Mocomtech CDM-570L Modem User Manual


 
Page 15 of 54 MN/CDM570L.AA4
33
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Reset Unit RST 1 byte value.
1 - reset the
system.
Command only.
Setting the parameter to 1 resets the system. Telnet2 connection
needs to be re-established.
RST=
RST!
N/A RST=x
(see description of
arguments)
Restore
Factory
Defaults
RFD 1-Byte value
1 - restore
Command only.
Setting this to ‘1’ will bring the modem back to factory defaults. This
may force unit reboot, depending on the mode of operation.
RFD=
RFD!
N/A RFD=x
(see description of
arguments)
Load Params
from
permanent
storage
LPS= 1-Byte value
1 – load
parameters
Command only.
Setting this to ‘1’ loads the system with parameters from permanent
storage/flash. This may force unit reboot, depending on the mode of
operation.
LPS=
LPS!
N/A LPS=x
(see description of
arguments)
Codecast
Multicast
Address
CCA= Multicast IP
Address in
xxx.xxx.xxx.
xxx format
Command or Query.
Set the Code cast multicast address, through which the modem can
receive the software updates via vLoad application. Only Multicast
address in the range 224.xxx.xxx.xxx To 239.xxx.xxx.xxx are
allowed. There are some reserved multicast addresses which cannot
be used.
This cannot be deleted.
CCA=
CCA!
CCA? CCA=xxx.xxx.xxx.xxx
(see description of
arguments)
Unit Up Time N/A String value Query only
Displays the unit up time in days, hours, minutes & seconds.
Example: >0001/uut=0 days 0 hours 13 mins 15 secs
N/A UUT? UUT=sssssss
String.
(see description of