Mocomtech CDM-570L Modem User Manual


 
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Front Panel Operation MN/CDM570L.IOM
6–38
If Upper is selected, the following sub-menu is displayed:
Edit BUC Current Alarm Upper limit. This is accomplished by selecting
the digit to be edited, using the
arrow keys. The value of the digit is
then changed using the
arrow keys. The user should then press
ENTER. The range of current is 500 to 4000 mA.
If Lower is selected, the following sub-menu is displayed:
Edit BUC Current Alarm Lower limit. This is accomplished by selecting
the digit to be edited, using
arrow keys. The value of the digit is
then changed using
arrow keys. The user should then press
ENTER. The range of current is 0 to 3000 mA.
(CONFIG, ODU, BUC) LO
If LO is selected, the following sub-menu is displayed:
Edit the value of the BUC LO frequency. This is accomplished by selecting the
digit to be edited, using the
arrow keys. The value of the digit is then
changed using the
arrow keys. The user should then press ENTER. The
valid range is from 3000 to 65000 MHz.
Note this value is used to display the RF frequency of the modem/BUC
combination. If a value of 00000 is entered here (the default), then no RF
frequency will be displayed on the CONFIG, Tx, Tx Freq menu.
BUC Current Alarm Upper
Limit:1200mA ( , ,ENT)
BUC Current Alarm Lower
Limit:1200mA ( , ,ENT)
BUC LO Frequency:
12000 MHz ( , ,ENTER)