Mocomtech CDM-570L Modem User Manual


 
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Front Panel Operation MN/CDM570L.IOM
6–52
6.16 INFO (Information)
Select All, Tx, Rx, Buf, Frame, Intfc, Rem, Mask, Red, ID or 1:1, using the
arrow keys, then press ENTER.
These screens display information on the current configuration of the unit. Depending on
the choice selected, one of the following screens will be displayed:
6.16.1 (INFO) ALL
This works in an identical fashion to CONFIG, ALL. It sequentially displays all
CONFIG screens, but does not permit the user to edit a config, just to view it.
6.16.2 (INFO) TX (Transmit information)
The information displayed here is as follows:
Top line:
Transmit Frequency and Data Rate (NOTE: Due to space limitations, the resolution of
displayed frequency is limited to 1 kHz, and data rate to 10 bps)
FEC Encoder type (VIT = Viterbi, VRS=Viterbi + Reed-Solomon,
TCM = Trellis Coded + Reed-Solomon, TUR = Turbo, UNC = uncoded)
Bottom line:
Modulation type (Q = QPSK, OQ= OQPSK, B = BPSK, 8P = 8-PSK, 8Q = 8QAM,
16=16-QAM).
Code Rate (Unc = Uncoded, 2144 = 21/44, then 5/16, 1/2, 2/3, 3/4, 7/8, 0.95)
Scrambler state (S = Scrambler on, N = Scrambler off, I = IESS-315 On)
Clocking Mode (INT = internal, EXT = external, LOP = loop)
Output power level
Transmit output state (ON = on , OF = off,
EO= external off, RT= Rx-Tx Inhibit)
TSI state (I = Transmit Spectral Inversion on, N = off)
INFO:All Tx Rx Buf Frame
Intfc Rem Msk Ref ID 1:1
Tx:1140.000 5000.000 TUR
8P 0.95 S EXT -20.0 ON I