Mocomtech CDM-570L Modem User Manual


 
CDM-570/570L Satellite Modem with Optional IP Module Revision 4
Serial Remote Control MN/CDM570L.IOM
13–10
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
AUPC Enable AUP=
1 byte, value
of 0 or 1
Command or Query.
AUPC mode enable/disable, where:
0=Disabled
1=Enabled
Example: AUP=1
Note: EDMAC framing must be selected for the AUPC feature to
work.
AUP=
AUP?
AUP*
AUP#
AUP?
AUP=x
(see description of
arguments)
AUPC
Parameters
APP=
6 bytes Command or Query.
Defines AUPC operating parameters. Has the form abc.cd, where:
a=Defines action on max. power condition.
(0=do nothing, 1=generate Tx alarm)
b=Defines action on remote demod unlock.
(0=go to nominal power, 1=go to max power)
c=target Eb/No value, for remote demod, from 0.0 to 9.9 dB
d =Max increase in Tx Power permitted, from 0 to 9 dB
Example: APP=015.67 (Sets no alarm, max power, 5.6 dB target
and 7 dB power increase.)
(Command not valid in Manual mode)
APP=
APP?
APP*
APP#
APP? APP=abc.cd
(see description of
arguments)
Remote Eb/No N/A
4 bytes
Query only.
Returns the value of Eb/No of the remote demod.
Responds 99.9 = remote demod unlocked.
Responds xx.x if EDMAC is disabled.
xx.x=02.0 to 16.0
Example: REB=12.4
Note: For values > 16.0 dB, the reply will be 16.0
N/A REB? REB=xx.x
(see description of
arguments)
Tx Power
Level Increase
N/A 3 bytes Query only.
Returns the increase in Tx power level, in dB (from the nominal
setting) due to the action of AUPC. Range is 0.0 to 9.9 dB
Responds x.x if AUPC is disabled.
Example: PLI=2.3
N/A PLI? PLI=x.x
(see description of
arguments)