Registered Gateway Details
The Registered Gateway Details screen presents a real-time display of the special operating parameters of the
Single Port Protocol (SPP). These are configured in the Call Signaling screen and in the Add/Edit Outbound
Phone Book screen.
Figure 6-7: Registered endpoints
Registered Gateway Details: Field Definitions
Field Name
V
alues Description
Column Headings
Description alphanumeric This is a descriptor for a particular VOIP gateway unit. This descriptor should
generally identify the physical location of the unit (e.g., city, building, etc.) and
perhaps even its location in an equipment rack.
IP Address
n.n.n.n
The RAS address for the gateway.
Port
n
Port by which the gateway exchanges H.225 RAS messages with the gatekeeper.
Register
Duration
The time remaining in seconds before the TimeToLive timer expires. If the gateway
fails to reregister within this time, the endpoint is unregistered.
Status Registered/
unregistered
The current status of the gateway either registered or unregistered.
No. of Entries The number of gateways currently registered to the Registrar. This includes all SPP
clients registered and the Registrar itself.
Details
Count of
Registered
Numbers
If a registered gateway is selected (by clicking on it in the screen), The "Count of
Registered Numbers" will indicate the number of registered phone numbers for the
selected gateway. When a client registers, all of its inbound phonebook's phone
numbers become registered.
List of
Registered
Numbers