NETGEAR M7100-24X Switch User Manual


 
IPv6 Multicast Commands
435
ProSafe M4100 and M7100 Managed Switches
The following table is displayed to indicate all the sources associated with this group.
Source Address
Uptime
Expiry Time
Example: The following shows examples of CLI display output for the commands.
(Switch) #show ipv6 mld groups ?
<group-address> Enter Group Address Info.
<slot/port> Enter interface in slot/port format.
(Switch) #show ipv6 mld groups 0/1
Group Address.................................. FF43::3
Interface...................................... 0/1
Up Time (hh:mm:ss)............................. 00:03:04
Expiry Time (hh:mm:ss)......................... ------
(Switch) #show ipv6 mld groups ff43::3
Interface...................................... 0/1
Group Address.................................. FF43::3
Last Reporter.................................. FE80::200:FF:FE00:3
Up Time (hh:mm:ss)............................. 00:02:53
Expiry Time (hh:mm:ss)......................... ------
Filter Mode.................................... Include
Version1 Host Timer............................ ------
Group compat mode.............................. v2
Source Address ExpiryTime
----------------- -----------
2003::10 00:04:17
2003::20 00:04:17
show ipv6 mld interface
Use this command to display MLD-related information for the interface.
Format show ipv6 mld interface [<slot/port>]
Mode
• Privileged EXEC
• User EXEC
Field Description
The IP address of the source.
Time elapsed in hours, minutes, and seconds since the source has been known.
Time left in hours, minutes, and seconds before the entry is removed.