Nortel Networks 553-3001-358 Server User Manual


 
Maintenance 177
Nortel Integrated Conference Bridge Service Implementation Guide
CS 2100/Meridian SL-100 diagnostic commands
Each card performs diagnostic tests as part of the daily routines.
Diagnostic tests can be activated from the MAP terminal on the CS
2100/Meridian SL-100. The ICB card appears as an extended digital
line card to the system. For the diagnostic routine to pass in the LTP
level of the MAP terminal, the feature Communicator must be assigned
to key 1 of the LEN.
Table 42 lists commands used to control the ICB status and functions.
Note: During a One Night Process (ONP), a no restart switch activity
(SWACT) to the other central processing unit (CPU) drops active
calls on the ICB card. A warm SWACT of the front end during
maintenance activities does not affect active calls on the ICB card.
TCP/IP connectivity test
Maintenance technicians can use “ping” to test if the LAN connection is
installed and configured properly. Perform a ping test in one of the
following ways (they are equivalent so there is no need to try both):
from a computer on the local LAN to the ICB card’s IP address
from the CLI (under the SMaint/ directory) to the IP address of a
computer on the local LAN
Table 42
CS 2100/Meridian SL-100 commands to enable/disable ICB channels
Command Operation performed
IPE MAP Level
Bsy Card x/ RTS card x Disable/enable specified card.
Tst Perform a network memory test, continuity test, and signaling test on the
specified loop.
QueryPM Inven Card x Get status of specified card.
LTP MAP Level
Bsy Make the LEN or DN busy.
Bsy INB Take the port out of service. The system does not generate alarms.
RTS Bring the ICB port in-service.