Provisioning Page 123 of 544
Option 11C and 11C Mini Technical Reference Guide
37 1016 989 967 949 933 919 909 898 889 881
38 1051 1022 1001 982 966 951 938 928 918 912
39 1083 1055 1035 1015 999 984 970 959 949 941
40 1117 1089 1066 1046 1029 1017 1002 990 981 972
Note: Load capacity is measured in CCS.
Table 29
Digitone receiver (DTR) load capacity — 16 to 25 second holding time
(Part 1 of 3)
Average
holding
time in
seconds
16 17 18 19 20 21 22 23 24 25
Number of
DTRs
1 0 0 0 0 0 0 0 0 0 0
2 2 2 2 2 2 2 2 2 2 2
3 8 8 8 8 8 8 8 8 8 8
4 18 18 18 18 18 17 17 17 17 17
5 31 31 31 30 30 30 30 30 30 29
6 47 46 46 45 45 45 45 44 44 44
7 64 63 63 62 62 62 61 61 61 60
Table 28
Digitone receiver (DTR) load capacity — 6 to 15 second holding time (Part 3 of 3)
Average
holding
time in
seconds
6 7 8 9 10 11 12 13 14 15
Number of
DTR’s