18 276 43 919
19 299 44 947
20 323 45 975
21 346 46 1003
22 370 47 1030
23 395 48 1058
24 419 49 1086
25 444 50 1115
Table 31
Digitone receiver (DTR) load capacity — 16 to 25 second holding time
(Part 1 of 3)
Average
holding
time in
seconds
16 17 18 19 20 21 22 23 24 25
Number of
DTRs
1 0 0 0 0 0 0 0 0 0 0
2 2 2 2 2 2 2 2 2 2 2
3 8 8 8 8 8 8 8 8 8 8
4 18 18 18 18 18 17 17 17 17 17
5 31 31 31 30 30 30 30 30 30 29
6 47 46 46 45 45 45 45 44 44 44
7 64 63 63 62 62 62 61 61 61 60
Table 30
Digitone receiver (DTR) requirements — Poisson 0.1 percent blocking (Part 2 of 2)
Number of DTRs DTR load (CCS) Number of DTRs DTR load (CCS)