Page 384 of 544 NT8D14 Universal Trunk Card
553-3011-100 Standard 14.00 January 2002
— or used for a four-wire non-VNL facility
• Non-Transmission Compensated
— used for a two-wire non-VNL trunk facility with a loss of less than
2 dB
— or used when impedance compensation is not provided
Table shows PAD settings and the resulting port-to-port loss for connections
between the Universal Trunk Card (UTC) and any other Intelligent Peripheral
Equipment (IPE) or Peripheral Equipment (PE) unit, denoted as Port B
In Option 11C systems, the insertion loss from IPE ports to IPE ports is as
follows.
Table 117
Insertion Loss from IPE Ports to IPE Ports (measured in dB)
IPE Ports
IPE Ports
500/2500
Line
Digital
Line
2/4 Wire
E&M Trunk
4 Wire
(ESN) E&M
Trunk
CO/FX
/WATS
Loop Tie
Trunk
CO/FX/
WATSLoop
Tie Trunk
2.5
0
0
-3.5
0.5
0
0
-0.5
0.5
0.5