![](http://pdfasset.owneriq.net/a/99/a9933c8c-a6bf-409f-96ad-2a6a14b125dd/a9933c8c-a6bf-409f-96ad-2a6a14b125dd-bg4f.png)
Memory, Storage and CPU capacity Page 79 of 544
Option 11C and 11C Mini Technical Reference Guide
Note 50
The following calculation applies to Template memory requirements:
HDT + (# of templates) * (avg. template length)
Where:
HDT = 4097 = size(TEMPLATE_HD_TBL)
Note 51
The protected data store requirements for Coordinated Dialing Plan (CDP)
(on a per-customer basis) are:
BASIC_ESN + SC x 3 + RL x (8 + 3 x RLE) + DME x (3 + I/4)
Priority Call Key 1
Private Call Key 2
SCI/CCOS/RMS 2
Signal Key 2
Speed Call Controller 1
Speed Call user 1
Stored number redial 1-8
Tenant Number 1
Time and Date Key 1
Voice call Key 2
Table 16
Feature memory requirements (Part 3 of 3)
Feature Memory Requirements