Paradyne JetFusion Integrated Access Device Network Card User Manual


 
2000-A2-GB20-10 - 128 - February 2004
Voice Path
Configura-
tion Menu
Configuring the voice path settings involves several tasks. These are all
displayed and accessed on the Voice Configuration menu (displayed by
typing P on the Main menu).
Tasks in this chapter are described beginning at the Voice Configuration
menu.
Figure 7–1. Voice Configuration Menu
Setting the
Voice Gate-
way
To select a voice gateway:
1. Type V on the Voice Configuration menu to select Set Voice Gateway.
The IAD displays the Voice Gateway Selection menu, which contains a list
of valid voice gateways for this IAD.
*******************************************
Voice Configuration
*******************************************
V. Set Voice Gateway
J. Set Jitter Delay
D. Display Jitter Delay
S. Set Start Mode (Loop Start/Ground Start)
T. Set SLIC Control Mode
U. Set Compander Mode (u-Law, A-Law)
O. Set On Hook Transmission Mode of Ground Start Lines
L. Set Idle Voltage Mode of Loop Start Lines
M. Set Debug Mode
E. Configure Echo Cancellation Default Settings
G. Set Loop Gain
C. Set Country Mode
NOTE
You must sign on as Supervisor to configure voice path
settings.
Be sure to reset the IAD when you are done making changes
to the voice path settings. Resetting the IAD causes the
configuration changes to take effect.
LAN LINK LAN ACT WAN LINK VOICEPOWER
POTS IADs
Figure 7-2 displays the list of valid gateways for all IADs
except those with an ISDN telephone interface. The order of
gateways varies by IAD.