Paradyne JetFusion Integrated Access Device Network Card User Manual


 
2000-A2-GB20-10 - 253 - February 2004
Table B–3. Country Code Settings—Belgium2, Denmark, and Italy
Parameters Belgium2 Denmark Italy
Min. Flash Hook (ms) 90 90 90
Max. Flash Hook (ms) 130 130 130
Ring Frequency (Hz) 25 25 25
Receive Gain (dB) 0 0 0
Transmit Gain (dB) -7 -6 -7
Ref/Input Impedance
(Ohms)
150 + (830 // 72nF) 300 + (1000 // 220nF) 180 + (630 // 60nF)
Load Impedance
(Ohms)
600 400 + (500 // 330nF) 0 + (750 // 18nF)
JF2008
JF2104
JF2108
Ring frequency and impedance settings are automatically