Paradyne SNMP DSU Computer Hardware User Manual


 
MIB Descriptions
C-17
7610-A2-GB20-10
November 1997
Output Signal Table Objects
The Output Signal Table Objects contains entries for the output signals that can
be asserted by the unit, for the synchronous User Data port. Clarification for
objects contained in this table as it applies to the unit is provided below.
Table C-12. Output Signal Table Objects
Object
Description Setting/Contents
rs232OutSigName
(rs232OutSigEntry 2)
Contains the identification
of a hardware output signal.
Supports only the following
values:
cts(2) – Clear To Send
dsr(3) – Data Set Ready
dcd(6) – Received Line Signal
Detector
rs232OutSigState
(rs232OutSigEntry 3)
Contains the current signal
state.
Supports only the following
values:
on(2) – The signal is asserted
off(3) – The signal is deasserted
rs232OutSigChanges
(rs232OutSigEntry 4)
Indicates the number of
times that a signal has
changed from on to off, or
off to on.
Increments the object each time
that the signal is sampled (every
100 ms) and the signal state is
different from the previous state.