Configuration Option Tables
A-4
7610-A2-GB20-10November 1997
Table A-1. System Options (3 of 3)
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows user-initiated tests to end automatically. Recommend enabling when the unit is
managed remotely through the IMC to avoid the requirement to terminate the test
manually.
Enable – User-initiated loopback and pattern tests end when test duration is reached.
Disable – Tests can be terminated manually from the Network Tests screen. Refer to
the
Network Tests
section of Chapter 7.
NOTE: Tests commanded by the DTE or network-initiated tests are not affected by
this test timeout.
Test Duration (min)
Possible Settings: 1–120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
H Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.
Security Violation Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Issues an alarm when access to the unit is attempted and fails.
Enable – Alarm generated when a security violation is detected. Refer to the
Trap: authentificationFailure
section of Appendix D for possible alarm causes.
Disable – No alarm generated for a security violation.