Paradyne SNMP DSU Computer Hardware User Manual


 
Testing
7-2
7610-A2-GB20-10
November 1997
Tests Available
From the Test menu, you can run network tests, data port tests, and a lamp test
for the front panel LEDs. Loopbacks can be initiated locally and remotely. Refer to
Loopbacks, Table 7-2.
The Test menu is limited to users with an access level of 1 or 2. To access the
Test menu, follow this menu selection sequence:
Main Menu
Test
Network tests require the participation of your network service provider.
The DSU supports physical-level tests independently on a per-interface basis.
H The CSU and DSU loopbacks and 511 test pattern send/monitor are
supported on the network interface.
H The Local Loopback and 511 test pattern send/monitor are supported on the
DTE port.
Network Tests
To access the Network Tests screen, follow this menu selection sequence:
Main Menu
Test
Network Tests
main/test/network
Device Name: Model: 7610
NETWORK TESTS
Test Command Status Result
CSU Loopback: Start Inactive 0:00:00
DSU Loopback: Start Inactive 0:00:00
Send V.54 Up: Send Sending
Send V.54 Down: Send Inactive
Send 511: Start Inactive 0:00:00
Monitor 511: Stop Active 125:08:48 Errors 99999+
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
R
esetMon
Use the Command column to start or stop a test by pressing Enter. The Result
column displays the test duration since the last device reset. When the Monitor
511 test is active, R
esetMon is available to reset the error counter to zero.
Selecting the Stop command on the Network Test screen or Abort All Tests from
the Test menu will not disrupt a network-initiated loopback.