Paradyne SNMP DSU Computer Hardware User Manual


 
Using the ATI
2-7
7610-A2-GB20-10
November 1997
Switching Between Screen Work Areas
Selecting Ctrl-a allows you to switch between the two screen work areas to
perform all screen functions. To access the screen function area below the dotted
line:
" Procedure
1. Press Ctrl-a to switch from the screen area to the screen function key area
below the dotted line. The available selections for the first input field appear
on the last line as shown below.
2. Select either the function’s designated (underlined) character or press the tab
key until you reach the desired function key.
Example:
To leave the current screen, enter e or E (Exit).
3. Press Return. The function is performed.
4. To return to the screen area above the dotted line, press Ctrl-a again.
main/configuration/edit/user/mgmt
Device Name: Model: 7610
MANAGEMENT PORT OPTIONS
Port Use: Net Link
Port Type: Synchronous
Clock Source: Internal
Data Rate(Kbps): 9.6
Routing Information Protocol:None
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu M
ainMenu Exit
S
ave
Select: None, Net Link, Alarms.
Ending a Session
Use the Exit function key from any screen to terminate the session.
" Procedure
1. Press Ctrl-a to go to the screen function key area below the dotted line.
2. Save changes if you have altered your configuration.
3. Select E
xit and press Return. The Main Menu appears.