Paradyne SNMP DSU Computer Hardware User Manual


 
Configuration Option Tables
A-7
7610-A2-GB20-10
November 1997
Table A-2. Network Interface Options (3 of 4)
No Signal Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When a NS condition is detected on the network interface, an ASCII alarm is generated.
Enable – Generates an ASCII alarm when a no signal condition is detected.
Disable – No ASCII alarm is generated.
NOTE: Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Out of Service Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When an OOS condition is detected on the network interface, an ASCII alarm is
generated.
H Out of Service Alarm option appears when the Operating Mode is set to DDS in
Table A-1.
Enable – Generates an ASCII alarm when an out of service condition is detected.
Disable – No ASCII alarm is generated.
NOTE: Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Out of Frame Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When an OOF condition is detected on the network interface, an ASCII alarm is
generated.
Enable – Generates an ASCII alarm when an out of frame condition is detected on the
network interface.
Disable – No ASCII alarm is generated.
NOTE: Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Excessive BPV Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When a Bipolar Violation condition is detected on the network interface, an ASCII alarm
is generated.
Enable – Generates an ASCII alarm when an excessive BPV condition is detected.
Disable – No ASCII alarm is generated.
NOTE: Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section
in Chapter 8.