4.8.2 Location ID On and Screen
Position Set
Pressing 2 in the LOCATION ID SETUP MENU will
turn the ID on at all times. It also allows you to posi-
tion the ID with the cursor control keys to the desired
screen display position.
4.8.3 Location ID Off
Pressing 3 will turn off the ID display.
4.9 CUSTOMER HEADER
(Selection #5 from the main menu)
The CUSTOMER HEADER is the message displayed
when the Inter-Check ICI1000S Series is being reset
and initialized. This text may be changed to reflect the
name of the customer’s store or company. Pressing 6 in
the MAIN PROGRAM MENU will allow changing the
customer header:
ENTER DATA WANTED UP TO 25 CHARACTERS
(ESC) TO SKIP, (ENTER) TO ENTER,
(BS) TO BACKSPACE
Enter the header desired up to 25 characters in length
and press ENTER to save.
NOTE: Performing a DEFAULT LOAD (DL)
in the Diagnostics Menu will return the cus-
tomer header to the default setting.
4.10 DIAGNOSTICS
(Selection #6 from the main menu)
WARNING: Some of the tests selected in the
DIAGNOSTICS MENU will cause the pro-
gramming in the Inter-Check ICI1000S Series
unit to be lost. These selections are preceded
by (DL) in the DIAGNOSTIC SELECTION
MENU.
NOTE: Some of the tests in the DIAGNOS-
TICS MENU can only be performed by fac-
tory trained personnel.
4.10.1 Program Transfer
The PROGRAM TRANSFER function is used for easy
duplication of the Inter-Check ICI1000S Series program.
This is especially useful for transferring exception pro-
gramming to multiple Inter-Check ICI1000S Series units
within the same chain of stores. Programming can also
be transferred to an IBM compatible PC. This requires a
software program which must be ordered directly from
Pelco. To accomplish a program transfer a simple cable
can either be made or may be ordered from Pelco. Refer
to Figure 7 for proper wiring.
Upon entering 1 in the DIAGNOSTICS MENU the
following prompt appears:
1. SOURCE 2. DESTINATION
After connecting the cable between the two Inter-Check
units, enter #1 for SOURCE on the Inter-Check ICI1000S
Series that is sending the program. Then enter #2 on the
DESTINATION Inter-Check unit, or the one that is re-
ceiving the program data. The program will then be sent
automatically. Upon detection of an error in transmission,
the system will retry until the proper data is received or
until manually aborted by pressing ESC.
CAUTION: Both units must have the same
memory map version. The memory map is dis-
played upon completion of initialization.
MM VER. X.X
4.10.2 (DL) Burn-In Test
(Test performed by Pelco personnel only)
4.10.3 (DL) Input Channel Port Test
(Test performed by Pelco personnel only)