Pelco ICI1000S Series Cash Register User Manual


 
Pelco Manual C1000M-B (1/96) 25
5.0 TROUBLESHOOTING
Symptom: System does not receive register data.
1. Power down the PIM, then repower it. If you re-
ceive a display on your monitor with a register
model number, the unit is receiving data from the
PIM.
2. Make sure the register model matches the number
displayed on the monitor.
3. Make sure the switch settings on your PIM are cor-
rect for your model register.
4. Verify that the communication setup and protocol
is accurate for your model register (non-PIM ap-
plications).
5. Check for proper wiring and hardware connections.
6. Refer to DEFAULT LOAD procedures in Section
4.10.8 of this manual.
7. Refer to PIM INSTALLATION procedures sup-
plied with your ICI1000PIM or Appendix B of this
manual.
Symptom: No text is displayed on the monitor.
1. Check camera and monitor connections.
2. Verify that the Inter-Check’s power supply is con-
nected.
3. Adjust potentiometers on bottom of the Inter-Check
unit.
Symptom: Inter-Check unit displays strange
character.
1. Check communication parameters and protocol.
2. Make sure baud rate is correct.
Symptom: Text vibrates on the monitor.
1. Adjust Vertical (V) on the bottom of the Inter-
Check unit.
2. Adjust Gain (G) on the bottom of the Inter-Check
unit.
Symptom: Red power indicator light on back of
unit is not lit.
1. Make sure power supply is plugged in properly.
2. Make sure outlet is working properly.
3. Ensure power supply is good (measure 5 volt out-
put).
4. Ensure that internal fuse is not blown.
Symptom: External serial printer not operating
properly.
1. Ensure proper wiring to the Inter-Check unit.
2. Set printer parameters at 1200 baud, 8 bits, no par-
ity.
Symptom: ERROR IN NV MEMORY message
appears on the monitor.
1. NV MEMORY write protect switch on the bottom
of the unit is in the locked position. Move to other
setting. (Refer to Section 4.2 and Figure 5.)
Symptom: RECEIVE ERROR, PLEASE
CHECK PARAMETERS is dis-
played on monitor.
1. Usually an indication of incorrect baud rate.
2. Also check protocol selection and communication
parameters.