Polaroid Polaview 305 Projector User Manual


 
9 Move the slide bar up or down until the image is displayed
properly.
If none of these adjustments corrects the problem, try a dif-
ferent Source mode selection. Make sure the selection has
the correct resolution and the closest V-sync and H-sync val-
ues.
Vertical double image
Adjusting the
vertical position
Use the SETUP key or the following procedure to adjust the
Vert. Pos. control.
1 Open the Main menu.
2 Select Advanced.
3 Select Vert. Pos. (vertical position).
4 Press the down arrow key until the image is properly
aligned.
Note: There are separate Vert. Pos. values for Normal and
Scale modes. Adjustments in one mode are not made in the
other.
If this adjustment does not correct the problem, try a differ-
ent Source mode setting. Make sure the selection has the
correct resolution and the closest V-sync and H-sync values.