Polycom 1725-36028-001 Server User Manual


 
Troubleshooting via the System Status Menu
Missed Slots: Occurs when the SpectraLink 8000 Telephony Gateway
does not have sufficient time to process audio. This number should
always be 0 or 1.
Buffer Overflow: Number of times Ethernet controller received more
packets than it had buffers to store them. Indicates extreme traffic.
Telephone Line Status
Each SpectraLink 8000 Telephony Gateway associates handsets with
lines from the host telephone system (PBX) as configured in the
system setup. Operational information about each handset connection
is provided through the
Telephone Line Status screen. This
information corresponds with the configuration information set up
from
Telephone Line Configuration option on the NetLink Wireless
Telephone System
menu.
When the SpectraLink 8000 Telephony Gateway needs to be
maintained, current call activity can be checked on this screen to
determine the level of service interruption a shut down will involve.
From the
System Status Menu, select Telephone Line Status. The
SpectraLink 8000 Telephony Gateway supports up to 16 lines.
A sample SpectraLink 8000 Telephony Gateway screen is displayed
below.
Line: Telephone line number (1-16).
PN: 1725-36028-001_T.doc 101