Install SpectraLink 8000 Telephony Gateway
Use only the provided Class II AC Adapter with output 24V DC, 1A.
For proper operation, all SpectraLink 8000 Telephony Gateways
must be powered on and off at the same time.
For installations with more than one SpectraLink 8000 Telephony
Gateway, use an outlet strip with a built in power switch to allow
SpectraLink 8000 Telephony Gateways to be turned on and off
together.
2. Plug the AC adapter into an 110V AC outlet or switch on the
outlet strip to apply power to the SpectraLink 8000 Telephony
Gateway.
3. Verify that leakage current ("touch" current) is below 250 μA rms
on exposed metal surfaces.
4. If leakage is excessive, power off the system and re-verify ground
path continuity.
5. The system will cycle through diagnostic testing and the LEDs
will blink for about one minute. When the system is ready for use:
— The E (error) LED should be off on each SpectraLink 8000
Telephony Gateway
— Status 1 should be blinking on each SpectraLink 8000
Telephony Gateway
— Status 5 should be lit on one and only one SpectraLink 8000
Telephony Gateway. If
Status 5 is lit on more than one
SpectraLink 8000 Telephony Gateway, the SpectraLink 8000
Telephony Gateways are not correctly connected to one
another.
PN: 1725-36028-001_T.doc 37