Q-Logic 3200 Network Card User Manual


 
1–Product Overview
Multi-boot Image for 10Gb Converged Network Adapter—CNA Function Configuration
SN0054671-00 B 1-9
Type
Enter to set a function to a particular type:
NIC—The function will support NIC protocol.
None—The function will be disabled.
iSCSI—The function will support iSCSI protocol.
FCoE—The function will support FCoE protocol.
MinBW%
Enter to specify the percentage of bandwidth allocated to the function. The
combined MinBW% values for a port’s functions cannot exceed 100 percent.
Protocol
The Protocol parameter applies only to only function 0 and function 1.
PXE—PXE will be supported on the NIC.
Adapter Settings
Press the ENTER key on the Function number to access Adapter Settings, and to
configure PXE Boot.
PXE. The following settings are available when Protocol is set to PXE:
Setup Menu Wait Time (0–15: the default is 5 seconds)
Specifies the time in seconds the menu will wait.
Enable PXE Boot (Enabled/Disabled: Default—Disabled)
Enter to toggle between Enabled and Disabled. Use the Enable PXE
Boot option to attempt a PXE boot on the selected function.
Restore to Non-NIC Partition Settings
Press the ENTER key to restore the NIC partition settings.
Exit the CNA Function Configuration Utility
Press the ENTER key to select from the following:
Reboot System
Return to Fast!UTIL
NOTE:
Functions 0 through 3 support only NIC or None. Functions 4 and 5 support
NIC, iSCSI, or None. Functions 6 and 7 support NIC, FCoE, or None.