35
systems operating in the VHF and
UHF bands. To monitor these
systems it is necessary to program
the scanner with three additional
parameters, the base frequency,
step and offset.
Ó
Follow these steps to program
Motorola trunking frequencies in
the VHF or UHF bands:
1. Press
PGM, and then TRUNK
to enter the ID program mode.
2. Press
FUNC and press (or
hold) S or T to select the
bank.
3. Press
MODE until Motorola
appears in the display.
4. Press
FUNC then 2.The
display indicates
Base Freq:
406.0000
Offset: 380
Step:25.0kHz
5. While B in Base blinks, if
necessary, enter the desired
Base frequency with the
number keys and press
ENTER.Ifitisincorrect,press
the number keys again to set
the base frequency.
6. While
O in Offset blinks, if
necessary, enter the offset
number and press
ENTER.Ifit
is incorrect, then press the
number keys again to set the
frequency.
7. While
S in Step blinks,
repeatedly press S or T to
select the step number, 5,
Ó HINTS Ó
• Base frequency,
step and offset vary
for each individual
UHF trunking
system. You can get
information about
these frequencies for
the trunking system
you want to scan
using
trunkscanner.com
,
other Internet
sources, or locally
published
guidebooks.
• Systems with
multiple channel
ranges can be
programmed using
PC application
software.