Settings You Can Change with User Tools
59
4
Timer Settings
❖
❖❖
❖ Auto Off Timer
After a specified time has elapsed following job completion, the machine au-
tomatically turns off in order to conserve energy. This function is called “Au-
to Off”.
The machine status after the Auto Off operation is referred to as “Sleep
mode”. For the Auto Off Timer, specify the time to elapse before Auto Off.
Note
❒ Default: 45 minute(s)
❒ Enter a time interval from 1 to 240 minutes, using the number keys
❒ Auto Off may not work when error messages appear.
❖
❖❖
❖ Energy Saver Timer
Set the amount of time the machine waits before switching to lower-power
mode after copying has finished or the last operation is performed.
The time can be set from 1 to 240 minutes using the number keys
Note
❒ Default: 15 minute(s)
❖
❖❖
❖ Panel Off Timer
Set the amount of time the machine waits before switching the panel off after
copying has finished or the last operation is performed.
Note
❒ The warm up time for making a copy from standby mode is 3 seconds for
Panel off Level 1 and 10 seconds for Panel off Level 2.
❒ Default: 60 seconds
❒ Enter a time interval from 10 to 999 seconds using the number keys
❖
❖❖
❖ System Auto Reset Timer
The System Reset setting automatically switches the screen to that of the func-
tion set in Function Priority, when no operations are in progress, or when an
interrupted job is cleared. This setting determines the system reset interval.
See p.53 “Function Priority”.
Note
❒ Default: On, 60 seconds
❒ The time can be set from 10 to 999 seconds, using the number keys
ThemisC1_AE_zentai_pre_FM.book Page 59 Thursday, July 28, 2005 2:13 PM