98
Chapter 7: What to Do If...
7-1 What to Do If...
The Machine Doesn't Run
The power does not switch on.
Is the main power switched on?
If the power does not come on when you press the [POWER] key, make sure the main power is switched on, then press
the [POWER] key again.
Printing doesn't start when data is sent.
Are the network settings correct?
Make sure there are no errors in the network settings. For more information about making the connection to a network,
see "Roland-PrintServer Network Settings Guide."
Has media been loaded (the SETUP LED is lit)?
If the SETUP LED is not illuminated, make sure the media is loaded correctly and press the [SETUP] key to illuminate
the SETUP LED.
Is the top menu displayed?
If the top menu isn't displayed, printing doesn't start even
when data is sent from the computer.
Is the PAUSE LED illuminated?
If the [PAUSE] key has been pressed and the PAUSE LED is lighted, the unit has been paused.
To resume printing, press the [PAUSE] key again. The PAUSE LED is extinguished, and printing resumes.
To terminate printing, first stop the transmission of printing instructions from the computer to this machine. Then press
the [SETUP] key. Hold down for about 1 second. This deletes the printing instructions that have already been sent from
the computer to this machine, and printing is stopped.
Has ink run out?
When printing data is sent while the screen shown in the
figure is displayed, a message appears and a warning beep
sounds.
At the same time, operation pauses. When the ink car-
tridge is replaced with a new one, printing starts.
The media width cannot be detected, even when the [SETUP] key is pressed.
Is [SHEET TYPE] set to [CLEAR]?
When [SHEET TYPE] is set to [CLEAR], the width of the media is not detected during media setup (and the printable
width is set to maximum).
When transparent media is loaded, specify a printing area that matches the actual width of the media. (Refer to "4-5
Using Transparent Media")
If opaque media is loaded, set [SHEET TYPE] to [OPAQUE].
Is the width of the loaded media 210 mm or less?
When media having a width of 210 mm or less is loaded, the width is not detected during media setup. Load media that
is at least 210 mm wide and perform setup again.
W 1234 mm
Top menu
1 2 3 4 5 6
7 8 9 10 11 12
This screen show cartridge No.1 and No.7 is run out.