SEAL 44Ultra Laminator Laminator User Manual


 
Disassembly / Reassembly Procedures
19
3. See figure 11. Disconnect the white
connector 1, located on the right-hand side
of the machine from the heater wire.
Remove the heater bracket by removing
the two bolts 2. Take care not to loose the
serrated washers.
The heating element can now be taken out of
the roller.
When a heating element has to
be installed into the roller, the
quartz tube has to be cleaned
first.
Proceed as follows:
Insert the heating element, with the end having the shortest wire, into the roller core. Make sure,
that the short wire is bent straight, to smoothen the insertion.
Whilst inserting, clean the quartz tube with a lint-free cloth, lightly dampened with IPA (Isopropanol).
Do not touch the quartz tube with your fingers!
This is important, because fingerprints will burn when the heater is on, and can possibly damage the
quartz tube. See figure 12.
Always be very careful when using IPA! IPA is very flammable!
The flash point of IPA is 11°C (51.8°F). The self-ignition temperature is 400°C
(752°F).
Once the element is placed in the roller,
reassemble all parts in reverse order.
fig. 11
2
1
fig. 12