Smart Technologies 600i4 Whiteboard Accessories User Manual


 
9 | CHAPTER 2 – ADDITIONAL DETAILS FOR INSTALLING YOUR INTERACTIVE
WHITEBOARD SYSTEM
Environmental
Requirement
Parameter
Operating temperature 41°F to 95°F (5°C to 35°C)
from 0' to 6000' (0 m to 1829 m)
41°F to 86°F (5°C to 30°C)
from 6000' to 9800' (1829 m to 2987 m)
Storage temperature -40°F to 122°F (-40°C to 50°C)
Humidity 30% to 70% relative humidity, non-condensing
Humidity above 80% might cause slight wrinkling in the
screen surface sheet. The wrinkles disappear when the
humidity lowers.
Water and fluid
resistance
Intended for indoor use only. Doesn’t meet any salt-spray
or water ingress requirements.
Don’t pour or spray liquids directly onto your interactive
whiteboard, the SMART UF65 or SMART UF65w
projector or any of its sub-components. See page 78
for detailed instructions on cleaning your interactive
whiteboard system.
Dust Intended for use in office and classroom environments.
Not for industrial use where heavy dust and pollutants
can cause malfunctions or impaired operation. Periodic
cleaning is required in areas with heavier dust. See
page 80 for information on cleaning the SMART UF65 or
SMART UF65w projector.
Designed for pollution degree 1 (P1) as per EN61558-1,
which is defined as “No pollution or only dry
non-conductive pollution”.
Electrostatic discharge
(ESD)
EN61000-4-2 severity level 4 for direct and indirect ESD
No malfunction or damage up to 8kV (both polarities) with
a 330 ohm, 150 pF probe (air discharge)
Unmated connectors meet no malfunction or damage up
to 4kV (both polarities) for direct (contact) discharge
Cables All SMART Board 600i4 or D600i4 interactive whiteboard
system cables should be shielded to prevent potential
accidents and degraded video and audio quality.
Conducted and
radiated emissions
EN55022/CISPR 22, Class A