CLI – Specify the hostname, location and contact information.
Displaying Switch Hardware/Software Versions
Use the Switch Information page to display hardware/firmware version
numbers for
the main board and management software, as well as the
power status of the system.
Field Attributes
Main Board
• Serial Number – The serial number of the switch.
• Number of Ports – Number of built-in RJ-45 ports and expansion
ports.
Console(config)#hostname R&D 5 4-33
Console(config)#snmp-server location WC 9 4-126
Console(config)#snmp-server contact Geoff 4-126
Console(config)#exit
Console#show system 4-79
System description :
SMC8748L2; Layer 2 Gigabit Ethernet Intelligent Switch
System OID string : 1.3.6.1.4.1.202.20.56
System information
System Up time : 0 days, 0 hours, 18 minutes, and 46.50
seconds
System Name : [NONE]
System Location : [NONE]
System Contact : [NONE]
MAC address : 00-12-CF-0B-0D-00
Web server : enabled
Web server port : 80
Web secure server : enabled
Web secure server port : 443
Telnet server : enable
Telnet port : 23
Jumbo Frame : Disabled
POST result
UART Loopback Test ........... PASS
DRAM Test .................... PASS
Timer Test ................... PASS
PCI Device 1 Test ............ PASS
I2C Bus Initialization ....... PASS
Switch Int Loopback Test ..... PASS
Fan Speed Test ............... PASS
Done All Pass.