B
ASIC
C
ONFIGURATION
3-27
• Password Threshold – Sets the password intrusion threshold, which
limits the number of failed logon attempts. When the logon attempt
threshold is reached, the system interface becomes silent for a specified
amount of time (set by the Silent Time parameter) before allowing the
next logon attempt. (Range: 0-120; Default: 3 attempts)
•Silent Time – Sets the amount of time the management console is
inaccessible after the number of unsuccessful logon attempts has been
exceeded. (Range: 0-65535; Default: 0)
• Data Bits – Sets the number of data bits per character that are
interpreted and generated by the console port. If parity is being
generated, specify 7 data bits per character. If no parity is required,
specify 8 data bits per character. (Default: 8 bits)
•Parity – Defines the generation of a parity bit. Communication
protocols provided by some terminals can require a specific parity bit
setting. Specify Even, Odd, or None. (Default: None)
• Speed – Sets the terminal line’s baud rate for transmit (to terminal) and
receive (from terminal). Set the speed to match the baud rate of the
device connected to the serial port. (Range: 9600, 19200, 38400, 57600,
or 115200 baud; Default: 9600 bps)
• Stop Bits – Sets the number of the stop bits transmitted per byte.
(Range: 1-2; Default: 1 stop bit)
Available in CLI only:
•Password – Specifies a password for the line connection. When a
connection is started on a line with password protection, the system
prompts for the password. If you enter the correct password, the
system shows a prompt. (Default: No password)
•Login – Enables password checking at login. You can select
authentication by a single global password as configured for the
Password parameter, or by passwords set up for specific user-name
accounts. (Default: Local)