6-6
TROUBLESHOOTING
2
Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the
paper cannot be removed, proceed to “C: Misfeed in the transport area”.
The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so
may cause a burn or other injury.
•
Do not touch the photoconductive drum (green portion) when removing the misfed paper.
Doing so may cause smudges on copies.
•
Do not remove the misfed paper from above the fusing unit. Unfixed toner on the paper
may stain the paper transport area, resulting in smudges on copies.
3
Raise the fusing unit release lever and then close the side cover by pressing the round
projections near the side cover open button. The misfeed ( ) indicator will go out and the
start (
) indicator will light up.
C: Misfeed in the transport area
1
Lower the fusing unit release lever.
See B: Misfeed in the fusing area (p. 6-5).
2
Open the front cover.
To open the front cover, see “TONER CARTRIDGE REPLACEMENT” (p. 5-2).
3
Rotate the feeding roller in the direction of the arrow and gently remove the misfed paper from
the exit area.
Feeding roller