Toshiba B-SX6T Printer User Manual


 
2. SYSTEM MODE EO13-33002
(Revision Date: Jul. 24, 2008)
2.1 Self-diagnostic Test
2- 7
• Descriptions of the Maintenance Counter
# Item Count Condition Range
(1)
Total media distance
covered
0.0 to 3200.0 km
(2) Media distance
covered
Counts when the feed motor is driven to feed, print or issue media.
(Counted also during a reverse feed.) See NOTE 2.
Destination printed on the same line indicates one selected for a
parameter clear.
0.0 to 3200.0 km
(3) Print distance Counts while printing. (Reverse feed is not counted.) See NOTE 3. 0.0 to 200.0 km
(4) Cut count Counts every cut. See NOTE 4. 0 to 1000000 times
(5) Head up and down
cycle count
Counts every head up and down cycle by means of the solenoid which
is used for the ribbon save function. See NOTE 4.
0 to 2000000 times
(6) Ribbon motor driving
time
Counts when the ribbon motor is driven to feed, print or issue media.
(The driving time is also counted during a reverse feed.) See NOTE 5.
0 to 2000 hours
(7) Solenoid drive time for
head up
Counts when the ribbon save function is activated. See NOTE 5. 0 to 1000 hours
(8) RS-232C hardware
error count
Counts when a parity, overrun or framing error occurs. See NOTE 6. 0 to 255 times
(9) System error count Counts when a system error occurs. 0 to 15 times
(10) Momentary power
failure count
Counts when a momentary power interruption occurs. 0 to 15 times
(80) Number of successful
RFID write
Counts when an RFID write has succeeded. 0 to 9999999 times
(81) Number of failure in
RFID write
Counts when an RFID write has failed. 0 to 9999999 times
NOTES:
1. Item from (2) through (10) are initialized to “0” after RAM clear.
2. If the media distance covered is 50.0 cm or less, it is rounded down and no data is added to the memory at power off.
3. If the print distance is 5.5 m or less, it is rounded down and no data is added to the memory at power off.
4. If the count is 31 or less, it is rounded down and no data is added to the memory at power off.
5. If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory at power off.
6. When a sent command results in an error, the same number as the data capacity of the command is counted by byte.