Toshiba B-SX6T Printer User Manual


 
2. SYSTEM MODE EO13-33002
(Revision Date: Jul. 24, 2008)
2.9 RFID Module Setting
2-81
2.9.9 RFID Write Retry Time-out
This parameter is to set the time-out for retry to write data onto an RFID tag.
If the printer does not succeed within the specified time-out, the printer stops, resulting in an error
(TIMEOUT). In case of frequent read errors, increase the amount of time. However, when the amount of
time is increased, a data read may become slower.
If the maximum number of retries is reached, the printer stops retry even before the specified time runs out.
The printer always reads an RFID tag for the specified time set by this parameter before writing data to the
RFID.
When “W CYCLE TIM 2.0” is displayed, press the [PAUSE] key.
Use the [FEED] or [RESTART] key to select a desired option. (Range: 0.0 sec. to 9.9 sec.)
[FEED] key: Pressing the [FEED] key one time causes a –0.1 change, up to 0.0.
[RESTART] key: Pressing the [RESTART] key one time causes a +0.1 change, up to 9.9.
After selecting the time-out, press the [PAUSE] key.
<10>RFID
W CYCLE TIM 2.0
[RESTART]
[FEED]
W CYCLE TIM 9.9
W CYCLE TIM 2.0
W CYCLE TIM 1.9
W CYCLE TIM 0.0