Toshiba B-SX6T Printer User Manual


 
2. SYSTEM MODE EO13-33002
(Revision Date: Mar. 26, 2009)
2.9 RFID Module Setting
2-76
2.9.3 RFID Tag Type Selection
This parameter is to choose an RFID tag type to be used. Available tag type is different depending on the
RFID module type.
When the RFID Module Type has been set to NONE
Use the [FEED] or [RESTART] key to select a desired option.
After selecting the RFID tag type to be used, press the [PAUSE] key.
2.9.4 RFID Error Tag Detection
This parameter is to choose whether an error detection is performed or not before writing data on an RFID
tag. When “ON” is selected, data is written on an RIFD only when no error is detected.
NOTE: This function is exclusively for Alien’s EPC CI Squiggle tag. Choose “OFF” usually.
When “ERR CHK OFF” is displayed, press the [PAUSE] key.
Use the [FEED] or [RESTART] key to select a desired option.
After selecting the RFID error tag detection function to be used, press the [PAUSE] key.
<10>RFID
TAG NONE
[RESTART]
[FEED]
TAG NONE
TAG EPC C1 Gen2
Tag type Parameter for TPCL command RFID module type
NONE 00
EPC C1 Gen2 24
B-SX708-RFID-U2-EU-R, B-SX708-RFID-CN-R
NOTE: Combination of RFID module type and available tag type
<10>RFID
ERR CHK OFF
[RESTART]
[FEED]
ERR CHK OFF
ERR CHK ON
Error tag detection is not performed. A tag is read before
writing data on it, but data is always written regardless of
the header data of the tag.
Error tag detection is performed. (Only when the header
data of the RFID data is “A5A5”, data is written on the
RFID tag. This function is available only for Alien’s EPC CI
Squiggle tag only.)