Toshiba E-STUDIO900 Copier User Manual


 
PTM 2-75 B070/B071
SP1902 001 displays the web consumption. When the web consumption exceeds the
value set with SP1-902-4 (Web Near End), the machine indicates web near-end on
the operation display.
The machine still operates while the actuator [A] remains above the web end sensor
[B] undetected. The actuator arm of the actuator remains in contact with the supply
roller [C] and gradually lowers as the amount of web on the supply roller grows smaller
as it is fed to the take-up roller [D] above.
When the web runs out, the actuator drops into the web end sensor at [E] and the
sensor signal to the CPU displays SC550 on the operation panel display. In this
condition, a technician must install a new oil supply and cleaning web, and then reset
SP1902 001 to 0 to clear SC550.
B070D555.WMF
[A]
[B]
[C]
[D]
[E]