Toshiba E-STUDIO900 Copier User Manual


 
PTM 4-1 B070/B071
4. INSTALLATION
4.1 INSTALLATION REQUIREMENTS
4.1.1 ENVIRONMENT
1. Temperature Range:
10°C to 32°C (50°F to 89.6°F)
2. Humidity Range:
15% to 80% RH
3. Ambient Illumination:
Less than 1,500 lux (do not expose to direct sunlight
or strong light)
4. Ventilation:
Room air should turn over at least 3 times per hour
5. Ambient Dust:
Less than 0.075 mg/m
3
6. If the place of installation is air-conditioned or heated, do not place the machine
where it will be:
1) Subjected to sudden temperature changes
2) Directly exposed to cool air from an air-conditioner
3) Directly exposed to heat from a heater
7. Do not place the machine where it will be exposed to corrosive gases.
8. Do not install the machine at any location over 2,000 m (6,500 feet) above sea
level.
90
80
70
60
50
40
30
20
10
10 20 30
%Rh
27°C (80.6°F) 80%
32°C (89.6°F) 54%
32°C (89.6°F) 15%
10°C (50°F) 15%
Temperature
Operation
Range
B070I900.WMF