Toshiba E-STUDIO900 Copier User Manual


 
PTM 2-86 B070/B071
2.12.2 ENERGY SAVER MODE
Entering the energy saver mode
The machine enters energy saver mode when one of the following is done.
The Energy Saver Key is held down for a second.
The panel off timer runs out after the last job (User Tools - System Settings - Timer
Setting - Panel Off Timer: default setting is 60 s).
What happens in energy saver mode
When the machine enters energy saver mode, the fusing lamp drops to a certain
temperature and the operation panel indicators are turned off except for the Energy
Saver LED and the Power LED.
If the CPU receives the image print out command from an application (e. g. to print
data from a PC), the fusing temperature rises to print the data. However, the operation
indicators stay off.
Return to stand-by mode
If one of the following is done, the machine returns to stand-by mode:
The Energy Saver Mode key is pressed
An original is placed in the ADF
The ADF is lifted
A sheet of paper is placed in the by-pass feed table
Operation
Switch
Energy Saver
LED
Fusing Temp.
Approx.
Recovery Time
System +5V
On On
168°C (B070/90 cpm)
173
°
C (B071/105 cpm)
3 s On