Toshiba E-STUDIO900 Copier User Manual


 
PTM 2-76 B070/B071
SP1902 004 (Web Near End) can be adjusted to change the near-end period. The
defaults for and amount of web that remains for copying are different for NA and
EUR/A.
Near-End
Area Near-End Web Remaining
NA 90% 600K
EUR/A 86% 350K
The table below, provided for your reference, shows approximately how adjustment of
SP1902 002 affects the near-end and end displays on the B070 (90 cpm) or B071
(105 cpm).
Note that adjustment of SP1902 002 also affects SP1902 005 (Web Motor Control –
Web Motor Drive Interval (Low Speed)).
SP1902 002
*1
B070 B071 Low
Speed
Mode
*2
SP1902 004
*3
Near-End
Display
(Sheets)
*4
End Display
(Sheets)
Comments
20.7 s 17.0 s 25.3 s 90% 600K 670K NA Default
15.6 s 12.8 s 19.0 s 90% 450K 500K
12.1 s 10.0 s 14.8 s 90% 350K 385K
10.4 s 8.5 s 12.7 s 90% 300K 330K
6.9 s 5.7 s 8.5 s 90% 200K 220K
12.6 s 10.4 s 15.4 s 86% 350K 410K EUR/A Default
10.8 s 9.0 s 13.2 s 86% 300K 350K
7.2 s 6.0 s 8.8 s 86% 200K 230K
*1
:
SP1902 002 (Web Motor Control – Web Motor Drive Interval)
*2
: SP1902 005 (Web Motor Control – Web Motor Drive Interval (Low Speed))
*3
: SP1902 004 (Web Motor Control – Web Near End Setting)
*4
:
Calculated based on A4 LEF at 100% magnification.
NOTE: SP1902 003 (Web Motor Control – Web Near End Setting) not adjusted.