PTM 2-72 B070/B071
2.9.5 DRUM ANTI-CONDENSATION HEATER
The drum anti-condensation heater [A] is located under the transfer belt unit. It turns
on when the main switch is off to prevent moisture from forming on the transfer belt.
The heater is included in the machine at the factory, but the connector is not
connected.
B070D048.WMF
[A]