Toshiba MR-3022 Scanner User Manual


 
MR-3018/3020/3021/3022 © 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
5 - 10
[B] Adjustment
Simplex copying:
(1) Shift the aligning plate with the scale as the guide shown in the figure below to adjust the skew.
Fig. 5-20
(2) If the image skew is "C" as shown in the figure below, shift the aligning plate in the direction of
"+", and if "D", shift it to "-".
Fig. 5-21
Fig. 5-22
Shift the aligning plate in the direction of "+". Shift the aligning plate in the direction of "-".
C
D
05/12