6.1 Troubleshooting for Mechanical Errors
1) Multiple originals are transported simultaneously
2) Original is not transported to registration roller
3) Leading edge of original is skewed
4) Edges of original and copied image are not aligned
5) Black streaks appear on copied image
Original abnormally curled or folded?
YES Flatten the original and set it again
NO
Separation roller is dirty?
YES Clean the roller with alcohol
NO
Replace the separation rollers with new ones
Original thicker than specified?
YES Use originals with permissible thickness.
Place thick originals manually on the platen cover to make a copy
NO
Pickup roller and feed roller are dirty?
YES Clean the rollers with alcohol
NO
Transport power of pickup roller and feed roller is weak?
YES
Replace the rollers with new ones
Front and rear protrusions at bottom of RADF are out of contact with glass?
YES Adjust the height of the left hinge
NO
Transport rollers are dirty?
YES Clean the rollers with alcohol
NO
Is the right hinge out of place?
YES
Make a copy and adjust the position of the hinge
Width between slides too wide compared to that of original?
YES Move the slides so that they contact the edges of the original
NO
Check the scanner adjustment
ADF original glass is dirty?
YES Clean the glass with a dry/squeezed cloth
NO
Check the scanner unit