278
Using the RAID-0 or RAID-1 Utility
Rebuilding the data on the secondary disk in a RAID-1 array
5.375 x 8.375 ver 2.3
Rebuilding the data on the secondary disk in a
RAID-1 array
If the secondary hard disk has been removed from the
computer and you want to resume using the secondary hard
disk for mirroring, you must reinsert the secondary hard disk
drive into the computer.
If Auto Rebuild has previously been enabled on the Options
window of the TOSHIBA RAID Console, rebuilding will
start when the secondary hard disk drive is reinserted into the
computer.
If Auto Rebuild has not previously been enabled:
1 Insert the secondary hard disk drive into the computer.
2 Plug in the AC adapter and power on the computer. (The
computer must be running on power provided by the AC
adapter to perform these steps.)
When rebuilding the RAID-1 array, all existing data on the
secondary hard disk will be permanently erased and cannot be
recovered. Toshiba is not responsible for any loss of data on
the hard disk.
If a hard disk password has previously been assigned, the
password entry window will display. You must enter the hard
disk password to continue.
3 The message “Mirror is broken” displays. Click OK.
4 Start up the TOSHIBA RAID Console Utility by clicking
Start, All Programs. Then select TOSHIBA, RAID,
RAID Console.
5 Click Mirroring.
NOTE