Xantrex Technology XDC 600-20 Power Supply User Manual


 
Remote Analog Operation
TM-XDOP-01XN 4–9
Press the LCL/RMT button to begin remote operation via the analog interface.
SCPI
To select which setpoints to control via analog programming lines, use the
command:
SYST:REM:SOUR {AVOL|ACUR|AVC}
Where
AVOL (Analog VOLtage) selects only voltage to be programmed via the
analog programming lines
ACUR (Analog CURrent) selects only current to be programmed via the
analog programming lines
AVC (Analog Voltage and Current) selects voltage and current to be
programmed via the analog programming lines
To select the voltage level:
SYST:COMM:APR:LEV {5|10}
Where
“5” is the 0-5V range, and
“10” is the 0-10V range
To put the unit into remote control:
SYST:REM:STAT REM
Step # Do This You Will See
1ERROR MSGS
2
4 times
REMOTE SELECT
3
RS-232
4
or
Select desired option.
Analog V&I,
Analog V, or
Analog I
5
Setting is saved.
MENU
ENTER
ENTER
TM-XDOP-01XN.book Page 9 Monday, July 17, 2006 11:19 AM