Xantrex Technology XDC 600-20 Power Supply User Manual


 
Remote Operation
4–42 TM-XDOP-01XN
Identification Query
The identification query command returns a string that states the manufacturer,
model, serial number, and firmware revision.
*IDN?
may return “Xantrex, XDC 60-100, 100000, 3.000/0/0/0000.
Option Identification Query
*OPT?
or
SYST[<channel>]:OPTion?
The option identification query returns a string listing any reportable options that
are installed in the power supply. Reportable options are GPIB and CANbus, but
may include others in the future. A zero will be returned if no options are
installed.
Example:
*OPT? may return "GPIB, CANBUS" to indicate that both the GPIB and
CANbus (Multichannel/Current Share) options are installed.
SCPI Version Query
SYST:VERS?
will return the SCPI version to which the unit complies (for example 1997-0).
TM-XDOP-01XN.book Page 42 Monday, July 17, 2006 11:19 AM