Xerox 4635 Printer User Manual


 
PREINSTALLATION
Table 3-6. 4635 environmental and electrical requirements
(continued)
Electrical requirements
Audible noise Standby: Continuous: 52 dB (A)
Impulse: N/A
Operating: Continuous: 67 dB (A)
Impulse: 72 dB (A)
Optional peripheral cabinet U.S. and Canada, 60 Hz:
208/240 VAC (1 phase) or
208/220 VAC (Line 1 to Line 2);
15 amp service;
NEMA 6-15R or ANSI C73, 20R
KVA .9 in both standby and operating
International, 50 Hz:
200/230 VAC (1 phase);
15 amp service;
Power connector per local codes
Optional bypass transport The power requirements for the bypass transport module
are all satisfied by the 4635 LPS printer module.
Agency certification UL, CSA, IEC, VDE
4635 LPS power receptacle requirements
All power outlets must be dedicated only to this equipment.
Ensure that each power cord has a separate circuit.
You must use a power cord assembly (ELCI, RCD Inline, 220
VAC) when using a source other than the system controller to
provide power to your PC UI. Contact your sales and service
representative to ensure the proper assembly is ordered and
installed.
Ensure that the power cord configurations match your receptacle
requirements (tables 3-7 and 3-8).
50 Hz systems: Consult with your local service representative to
determine the type of plug and receptacle to use with your 50
Hz printer and system controller.
Table 3-7. Printer power receptacle requirements
Electrical environment Voltage/current Receptacle
U.S. and Canada 60 Hz 120/240/50A or
120/208/50A
NEMA 14-50R
International 50 Hz WYE 380,400,415/20A (WYE),
3 Phase, 5 wire
Per local code
International 50 Hz DELTA 220,230, 240/30A (DELTA),
3 Phase, 4 wire
Per local code
3-16 XEROX 4635 LASER PRINTING SYSTEM INSTALLATION PLANNING GUIDE