ZyXEL Communications 153X Network Router User Manual


 
Prestige 153/153X WAN Bridge/Routers
System Maintenance 13-5
13.2 Terminal Baud Rate
You can set up different baud rates for the console port through Menu 24.2 - Terminal Baud Rate.
Your Prestige supports 9600 (default), 19200, 38400, 57600, and 115200bps for the console port.
Use the space bar to select the desired baud rate in Menu 24.2, as shown in Figure 13-4.
Figure 13-4. Menu 24.2 - System Maintenance - Change Terminal Baud Rate
13.3 Log and Trace
There are two logging facilities in the Prestige. The first is the error logs and trace records that
are stored locally. The second is the UNIX syslog facility for message logging.
13.3.1 Viewing Error Log
The first place you should look for clues when something goes wrong is the error/trace log.
Follow the procedure below to view the local error/trace log:
Step 1. Select option 24 from the Main Menu to open Menu 24 - System Maintenance.
Step 2. From Menu 24, select option 3 to open Menu 24.3 - System Maintenance - Log and
Trace.
Step 3. Select the first option from Menu 24.3 - System Maintenance - Log and Trace to
display the error log in the system.
After the Prestige finishes displaying, you will have the option to clear the error log.
Menu 24.2 -- System Maintenance - Change Terminal Baud Rate
Terminal Baud Rate: 115200
Press ENTER to Confirm or ESC to Cancel:
Press Space Bar to Toggle.