ZyXEL Communications ES-2024 Series Switch User Manual


 
Chapter 14 Mirroring
ES-2024 Series User’s Guide
114
The following table describes the labels in this screen.
Table 29 Advanced Application > Mirroring
LABEL DESCRIPTION
Active Select this check box to activate port mirroring on the Switch. Clear this check box to
disable the feature.
Monitor
Port
The monitor port is the port you copy the traffic to in order to examine it in more detail
without interfering with the traffic flow on the original port(s). Enter the port number of the
monitor port.
Ingress You can specify to copy all incoming traffic or traffic to/from a specified MAC address.
Select All to copy all incoming traffic from the mirrored port(s).
Select Destination MAC to copy incoming traffic to a specified MAC address on the
mirrored port(s). Enter the destination MAC address in the fields provided.
Select Source MAC to copy incoming traffic from a specified MAC address on the
mirrored port(s). Enter the source MAC address in the fields provided.
Egress You can specify to copy all outgoing traffic or traffic to/from a specified MAC address.
Select All to copy all outgoing traffic from the mirrored port(s).
Select Destination MAC to copy outgoing traffic to a specified MAC address on the
mirrored port(s). Enter the destination MAC address in the fields provided.
Select Source MAC to copy outgoing traffic from a specified MAC address on the
mirrored port(s). Enter the source MAC address in the fields provided.
Port This field displays the port number.
* Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row
first to set the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you
make them.
Mirrored Select this option to mirror the traffic on a port.
Direction Specify the direction of the traffic to mirror by selecting from the drop-down list box.
Choices are Egress (outgoing), Ingress (incoming) and Both.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top navigation
panel to save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.