ZyXEL Communications ES-2024 Series Switch User Manual


 
Chapter 27 Access Control
ES-2024 Series User’s Guide
200
voltage VoltageEventOn 1.3.6.1.4.1.890.1.5.8.27.27.2.1 This trap is sent when the voltage
goes above or below the normal
operating range.
VoltageEventClear 1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the voltage
returns to the normal operating
range.
reset UncontrolledResetEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when the Switch
automatically resets.
ControlledResetEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when the Switch
resets by an administrator through a
management interface.
RebootEvent 1.3.6.1.4.1.890.1.5.1.1.2 This trap is sent when the Switch
reboots by an administrator through
a management interface.
timesync RTCNotUpdatedEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when the Switch
fails to get the time and date from a
time server.
RTCNotUpdatedEventClear 1.3.6.1.4.1.890.1.5.8.16.27.2.2
1.3.6.1.4.1.890.1.5.8.27.27.2.2
This trap is sent when the Switch
gets the time and date from a time
server.
intrusionloc
k
IntrusionLockEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when intrusion lock
occurs on a port.
loopguard LoopguardEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when loopguard
shuts down a port.
Table 76 SNMP System Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
Table 77 SNMP Interface Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
linkup linkUp 1.3.6.1.6.3.1.1.5.4 This trap is sent when the
Ethernet link is up.
LinkDownEventClear 1.3.6.1.4.1.890.1.5.8.16.27.2.2
1.3.6.1.4.1.890.1.5.8.27.27.2.2
This trap is sent when the
Ethernet link is up.
linkdown linkDown 1.3.6.1.6.3.1.1.5.3 This trap is sent when the
Ethernet link is down.
LinkDownEventOn 1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when the
Ethernet link is down.
autonegotiation AutonegotiationFailedEventO
n
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
This trap is sent when an
Ethernet interface fails to auto-
negotiate with the peer Ethernet
interface.
AutonegotiationFailedEventC
lear
1.3.6.1.4.1.890.1.5.8.16.27.2.2
1.3.6.1.4.1.890.1.5.8.27.27.2.2
This trap is sent when an
Ethernet interface auto-
negotiates with the peer
Ethernet interface.