ZyXEL Communications ES-3124PWR Switch User Manual


 
ES-3124PWR Ethernet Switch
4-8 Introducing the Web Configurator
Figure 4-4 Reload the Configuration file: Via Console Port
The switch is now reinitialized with a default configuration file including the default password of “1234”.
4.5.2 Reset to the Factory Defaults
To reset the switch back to the factory defaults, do the following:
Step 1. Connect to the console port using a computer with terminal emulation software. See the chapter on
hardware connections for details.
Step 2. Disconnect and reconnect the switch’s power to begin a session. When you reconnect the switch’s power,
you will see the initial screen.
Step 3. When you see the message “Press any key to enter Debug Mode within 3 seconds
press any key to enter debug mode.
Step 4. Type atbr after the “Enter Debug Mode” message.
Figure 4-5 Reset the Switch: Via Console Port
Step 5. After the resetting, type atgo to restart the switch.
Bootbase Version: V0.1 | 02/01/2005 16:33:32
RAM:Size = 32 Mbytes
DRAM POST: Testing: 32768K OK
DRAM Test SUCCESS !
FLASH: Intel 32M
ZyNOS Version: V3.60(TY.0)b1.1 | 04/15/2005 17:08:38
Press any key to enter debug mode within 3 seconds.
..................
Enter Debug Mode
ES-3124PWR> atlc
Starting XMODEM upload (CRC mode)....
CCCC
Total 393216 bytes received.
Erasing...
...........................................................................
.....OK
ES-3124PWR> atgo
Bootbase Version: V0.1 | 02/01/2005 16:33:32
RAM:Size = 32 Mbytes
DRAM POST: Testing: 32768K OK
DRAM Test SUCCESS !
FLASH: Intel 32M
ZyNOS Version: V3.60(TY.0)b1.1 | 04/15/2005 17:08:38
Press any key to enter debug mode within 3 seconds.
................
Enter Debug Mode
ES-3124PWR> atbr
Restore default
Romfile.........................................................
..........OK
ES-3124PWR> atgo